Model
AUT-501 Automatic Titration System
|
| |
|
The
AUT-501 Titrator is a high performance microprocessor
controlled titration system which will perform all types
of classical titration routines. The AUT-501 titrator
and peripherals are the result of many years experience
in electrochemical Instrument Manufacturing.

|
| |
Features
|
-
pH,
Redox, pH stat, Amperometric, Conductometric, and
Photometric Titrations can be performed.
-
Use
up to (10) ABT-511 burettes to Perform linked titrations
and automated sequential titrations using different
titration methods, preamplifiers, electrodes, burettes
and samples. Fully programmable for the most complex
procedures.
-
New
titration control for fast analysis time.
-
Conforms
to GLP and Y2K requirements. Includes a complete
electrode confirmation and replacement routine for
compliance and validation.
-
Results
memory for 100 measured samples and total re-analysis
function of previous data for latest 40 results.
-
True
Multi-tasking operation. Modify and re-analyze data
while titration is being performed.
-
True
bi-directional RS-232 operation. Analog Controls
also available (std.).
-
Options
include a multi-sampler for 12, 24, 36 or 60 samples,
Balance Interface, Computer interface, External
printer and Multiple preamplifiers (For multi-electrode
analysis).
-
Pre-defined(20
fixed) and User defined methods(30) are fully programmable
and available. The system includes 10 Linked Modes,
Buret Dispense modes, Calibration Mode and Potential
measurement Mode(s) as Standard.

|
| |
The
Keys to the System
|
|
The
keys to the system are the Methods which can be performed.
Methods include "Full Auto" for automatic end point
detection and "End Level" for pre-set end-point level
titration. pH Stat titration can be performed, and the
system allows for complete control and automation of
Conductivity ("V" and "L" type intersection) Methods.
A Special Algorithm for ASTM D-664 and D-2896 Petroleum
Neutralization Titration are also built-in. Also a few
special routines are built in for Acidity, Salinity,
Alkali, and Total Hardness.
The Control parameters are fully programmable and extremely
flexible to accommodate the most demanding titration
requirements. Full calculation control for up to 5 end
points, linking of multiple titration using multiple
pre-amps is possible. Amperometric and colorimetric
analysis is simple with the available sealed titration
cell, photometric adapter and wide range on electrode
systems.
|
| |
<Model
AUT-501> Titration System Accessories
|
Multiple
Pre-amplifiers:
|
|
Multiple
preamplifiers for different types of chemistries. The
AUT-501 can incorporate up to three preamplifiers at
one time for differing applications.
These include the standard pH/mv preamp, a Photometric
preamp, a conductometric preamp and an amperometric
preamplifier. Add an electronic balance to automatically
input weights into the memory of the system.
|

|
| |
<Model
AUT-501> Titration System Accessories
|
Automated
Sampler
|
|
An
Automated Sampling device for 12, 18 or 32 or 60 samples
(measurement only, no titration available for 60-sample
setting). This Sampler incorporates an external wash
station with separate pumps for rinsing and showering
of electrodes. The sampler also uses standard 200 ml
tall beakers for the 12 position, 100 ml beakers for
the 18 position, 50 ml tall beakers for the 36 position
and 20 ml tall beakers for the 60 position sampler tray.
The sampler can also be used independently of the main
titrator via its RS232 control (Option). The system
has a number of predefined wash and rinse sequences
and has adjustable time controls built in.
|

|
| |
<Model
AUT-501> Titration System Accessories
|
RS232
Printer
|
|
The
AUT-501 includes a standard bi-directional RS232 interface
for complete control and output of the system parameters
and results.
|
 |
|

|
|
|